TK 1000/H

Aquarium Chiller

Aquarium Chiller

Efficient Cooling Technology
The exclusive use of high-quality and internationally accepted and of the titanium heat exchanger, ensures high performance and low energy consumption. The set of technologies used allow you to achieve the highest COP - coefficient of performance and the lowest noise levels.
Digital Thermostat
The setting of functions is intuitive and the temperature reading is accurate, resolution 0.1°C/1°F. The setting range is 5°C - 30°C (41°F - 86°F) and the temperature is kept constant with a maximum differential of 0.5°C/0.5°F. Displayed temperature is in °C or °F and there are security alarms.
Efficient Design
The chiller, with its innovative design, is characterized by a solid structure designed to guarantee a perfect protection against rust. The user will appreciate the functionality of the shape and the compact size also adaptable to confined spaces.
Unique Features
Innovative TECOair system: a system that, thanks to the conveyor rotation, assure to the chiller an optimal air exchange and heat expulsion from the cabinet; Magnetic filter for quick maintenance; R290 environmentally friendly gas that reduce power consumption with increased performance and COP; Designed for TECOnnect Wi-Fi.
Optional: it is possible to request the unit with the resistance.
Water temperature       Ambient temperature Liters/ US Gallons COP* Power supply
25°C - 77°F       30°C - 86°F 1000 l/ 265 2,75 230V - 50Hz
8°C - 47°F       30°C - 86°F     
150 l/ 40 1,69 230V - 50Hz
25°C - 77°F       30°C - 86°F 1000 l / 265 2,58 115V - 60Hz
8°C - 47°F**       30°C - 86°F 150 l/ 40 1,57 115V - 60Hz
*Coefficient of performance.
Voltage Frequency Gas Weight Ambient temperature Power Consumption
230V 50 Hz
R290 19,7 kg / 43,4 lb 10°C - 38°C/ 50°F - 100°F 240 W (cooling)
115V 60 Hz
R290 19,7 kg / 43,4 lb 10°C - 38°C/ 50°F - 100°F 260 W (cooling)
230V 50 Hz R290 19,7 kg / 43,4 lb 10°C - 38°C/ 50°F - 100°F 300 W (heating)
115V 60 Hz R290 19,7 kg / 43,4 lb 10°C - 38°C/ 50°F - 100°F 300 W (heating)
ll data are approximate and may be changed without notice by TECO